Technology Features
- Stratified fluid piping design for two-channel measurement, measurement accuracy
- Range than the width, and less than 0.01m / s starting flow
- Display large amount of information, with the screen display 9 digital display four cumulative flow and instantaneous flow figures
- Design of energy-saving, power-saving features such as automatic meter will empty tube or long-term fluid standstill
- Full IP68 protection class design, the components completely sealed to protect, even if the water can be long-term work
- Design at the time, there were a total of records and data collection functions on the month, day
- With multiple communication interface mode; TTL level pulse output and USART interface for easy connection to other low power devices; standard RS485 interface;
infrared communication interface; support CJ-188 communication protocol.
- Supports standard MODBUS, M-BUS, HART communication protocol, compatible communications protocol Haifeng ASCa code
- Output signal and diverse: Available two isolated pulse signal output, ( which pulse and pulse width equivalent programmable) ; may also 4-20mA two-wire output
- With online software upgrades
- With Dual PT1000 temperature measurement function, can achieve heat measurement
- Built-quantitative control can be achieved manually or set the time automatically start controller, thus achieving automatic timing quantitative or
quantitative irrigation water
- Depending on customer needs to select a variety of units, including cubic US gallons, cubic feet and liters
- Built-in lithium battery, the battery life of more than 6 years
SPECIFICATIONS
Project
|
Parameter
|
Accuracy class
|
2 (measurement period: 1 second)
|
Turndown ratio
|
100, initiating a flow rate of less than 0.006m / s
|
Measurement Range
|
Water, sewage, water (and other liquids to be customized), and filled conduit
|
Medium temp measurement
|
0.1-30 ℃
|
Work Environment
|
Temperature: -10 ~ 45 ℃; humidity ≤ 100% (RH)
|
Pressure Rating
|
1.6MPa/2.5MPa optional
|
Upstream flow field sensitivity level
|
U3
|
Downstream flow field sensitivity level
|
D0
|
Climatic and mechanical environmental safety class
|
C grade
|
Electromagnetic Compatibility Level
|
E2 level
|
Communication Interface
|
RS485/USART / IR / USART serial communication bus, etc. Optional
|
The output signal
|
Two-wire 4-20mA analog outputs (OCT or two isolated TTL optional programmable pulse width)
|
Communication protocol
|
Haifeng fully compatible protocol (individual command very differentiated) also supports the standard MODBUS, M-BUS, CJ-188 communication protocol
|
Heat measurement
|
Access Dual PT1000 achieve heat measurement
|
Power supply
|
Built-in lithium battery (3.6V) / External DC5 ~ 40V
|
Protection class
|
IP68
|
Local Display
|
Two-line display includes nine accumulation, four instantaneous flow, as well as prompt and unit status
|
Data Storage
|
Using EEPROM / FLASH to store data, cumulative flow automatically record 128 months ago, 512 days ago
|
Flow measurement cycle
|
Measurement status: 1 times / sec (can also be set from 2 to 4 times / sec); verification status: 4 times / sec
|
Power and Power
|
Built-in 3.6V lithium battery can be used continuously for more than six years, external DC8-36V
|