Jumat, 06 Maret 2015

TECHNOTON DFM FUEL FLOW METER

Fuel flow meter DFM is designed for diesel fuel consumptionmeasuring in the fuel line of the following vehicles:
  • trucks;
  • tractive vehicles;
  • tractors of various types;
  • loaders;
  • graders;
  • road-building machinery;
  • boilers;
  • boats;
  • burners;
  • technological transport;
  • fixed installations with diesel engines etc.
  • Inline fuel meter DFM can be applied for fuel accounting both autonomously and as a part of vehicle tracking and fuel monitoring system.
Fuel gauge DFM allows to solve the following tasks:
fuel consumption control;
fuel consumption rationing;
fuel theft detecting and preventing;
fuel comsumption optimization and real-time monitoring;
engine fuel consumption testing.
Fuel meter DFM enables to receive objective information about actual fuel consumption and vehicle working time. It also permits to reduce fuel and repairing costs. It is possible to develop fuel consumption rates for selected routes and technological operations.

The economic effect of using the fuel accounting devices is different at various companies, usually about 10 to 40%, depending on the baseline situation and management persistence

DFM models designationDFM models choice for internal combustion engine/boiler
Fuelflow meters models designation for the ordering

Engine power,
kW

Boiler heat
productivity, 
kW

Recommended
inline fuel 
meters

Recommended
mounting kits
under 80under 400DFM 50№ 2
80-150400-800DFM 90,
DFM 100
№ 2
150-300800-1500DFM 220,
DFM 250
№ 4
300-5001500-3500DFM 400№ 4

Operating principle

Fuel gauge DFM has three-dimension ring type measuring chamber. DFМ generates an impulse, when the volume of fuel (which is equal to volume of the measuring chamber) passes through it.

Measured fluids

Fuel flow meter DFМ can be used for consumption measuring of the following fluids:diesel fuel;
  • heating oil;
  • engine oil;
  • other types of liquids with kinematic viscosity from 1.5 to 6 mm2/sec*.

Application for more viscous liquids is also possible, but the maximum consumption may get less than critical and the pressure on the meter gets down. All the meters DFM are tested with diesel fuel. Please specify the fuel type and viscosity in your order.
The materials resistant to gasoline are used for DFМ manufacturing. Use safety means in accordance with the national laws when working with gasoline.

Features
protection against unauthorized interference and tampering with the meter;
resistant to vibration and hydraulic impacts;
big in-built mud filter;
meets road standards of electromagnetic compatibility, mechanical and climatic influences;
durable and precise measurement zinc-aluminum chamber;
full set of mounting accessories;
all the fuel flow meters DFM are tested on the metrologically certified installation when produced.

Specification

Connecting threadM14x1.5
Nominal pressure, MPa0.2
MAX pressure, MPa2.5
Supply voltage, V10-50
Overvoltage protection, V≤100
Current consumption, mA≤25 (24 V)
≤50 (12 V)
Operating temperature, °Cwithout display: from -40 to +80;
with display: from -20 to +60



Mounting

Fuel meters DFМ are mounted into fuel line of vehicles according to approved installation schemes. Fuel pipe and mounting kit can be additionally included in delivery package.
We strongly recommend to seal pipe connections after the fuel flow meter output.

To get the detailed information about fuel gauges DFМ installation please contact to Technical Support.

Measurement scope and accuracy

ModelThe nominal boreStart-up consumption,
l/h
MIN flow rate,
l/h
MAX flow rate,
l/h
Inaccuracy,
±%
DFМ 50 AK, B, C, CK60.51501
DFМ 90 AP60.53902
DFМ 100 AK, B, C, CK60.521001
DFМ 220 AP8282202
DFМ 250 AK, C, CK8252501
DFМ 400 AK, C, CK1020304002





Kembali ke halaman sebelumnya






http://wmaflow.com/products/technoton-fuel-meter.html